Tech-Tip Reference # : TT51_Troubleshooting 2551 & 2552 Magmeters Date Posted :
12/17/2007

Troubleshooting the 2551 and 2552 Magmeters

The Signet 2551 and 2552 Magmeters feature two LED lights that are designed to assist in troubleshooting a problem system.
Knowing what the different light displays mean can be extremely helpful in resolving field problems.

light location2551 The lights on the 2551 Magmeter are located on the circuit board inside the yellow enclosure. light location2552 The lights on the 2552 Metal Magmeter are located at the top of the magmeter, recessed inside the threaded steel housing. Look down the tube to see them.

Troubleshooting with the RED and BLUE lights 
No Lights: The power is off or the sensor is not connected.
Frequency and Digital (S3L) Magmeters: Check for 5 VDC at BLACK (+) and WHITE (GND) wires. 4-20 mA Magmeters: Check for 24 VDC at BLACK (+) and WHITE (GND) wires.
Solid Blue: The power is on but there is no flow in the pipe.
This is the normal indication when the pipe is full, but the water is not moving.
If there is flow in the pipe, look for shorted electrodes at the tip of the mag sensor.
Blinking Blue: Normal operation, blink rate is proportional to the flow rate.
Alternating Red-Blue: Empty pipe indication (electrodes are not wet.)
Look for air pockets at the sensor location.
Blinking Red: System errors (electrical noise interference)
This indicates a problem with the power source and/or the grounding points in the Magmeter wiring.
Solid Red: Instrument error (defective electronics component)
The magmeter is inoperative and must be returned to the factory for service.

Replacement Transducers
Mfr. Part No. Code Description
3-2551-P0 159 001 211 PP/316L SS, DN15 to DN100 (½ to 4 in.) pipe
3-2551-P1 159 001 212 PP/316L SS, DN125 to DN200 (5 to 8 in.) pipe
3-2551-P2 159 001 444 PP/316L SS, DN250 to DN300 (10 to 12 in.) pipe
3-2551-T0 159 001 213 PVDF/Titanium, DN15 to DN100 (½ to 4 in.) pipe
3-2551-T1 159 001 214 PVDF/Titanium, DN125 to DN200 (5 to 8 in.) pipe
3-2551-T2 159 000 445 PVDF/Titanium, DN250 to DN300 (10 to 12 in.) pipe
3-2551-V0 159 001 376 PVDF/Hastelloy-C, DN15 to DN100 (0.5 to 4 in.) pipe
3-2551-V1 159 001 377 PVDF/Hastelloy-C, DN125 to DN200 (5 to 8 in.) pipe
3-2551-V2 159 000 446 PVDF/Hastelloy-C, DN250 to DN300 (10 to 12 in.) pipe
3-2551-W0 159 001 234 PVDF/316L SS, DN15 to DN100 (0.5 to 4 in.) pipe
3-2551-W1 159 001 235 PVDF/316L SS, DN125 to DN200 (5 to 8 in.) pipe
3-2551-W2 159 001 447 PVDF/316L SS, DN250 to DN300 (10 to 12 in.) pipe
  Related Product(s)
 

•  2551 Magmeter Flow Sensor
•  2552 Magmeter Flow Sensor

3401 Aerojet Avenue, El Monte, CA 91731-2882, U.S.A.
© 2007 Georg Fischer Signet LLC
  • For Sales, click HERE
  • For Technical Service and Support, click HERE